The part(s) or condition(s) listed below for the symptom Generator won't start are ordered from most likely to least likely to occur. Check or test each item, starting with the items at the top of the page.

Most Frequent Causes for Generator won't start

For the most accurate results, enter your model number.


Cause 1Spark Plug

Inspect the spark plug for signs of wear or damage. If the porcelain insulator is cracked, an electrode is burned away or damaged, or there is heavy carbon buildup at the electrode, replace the spark plug. To determine if the spark plug is defective, use a spark plug tester. You should see a strong spark between the tester’s terminals when the engine is cranking. If there is no spark, this indicates that the spark plug is defective and should be replaced.

Parts
Cause 2Carburetor

The carburetor might be clogged. A clogged carburetor is most commonly caused by leaving fuel in the generator for a long period of time. Over time, some of the ingredients in the fuel may evaporate, leaving behind a thicker, stickier substance. This sticky fuel can clog up the carburetor and prevent the engine from starting. If the carburetor is clogged, try cleaning it with carburetor cleaner. If cleaning the carburetor isn’t effective, rebuild or replace the entire carburetor.

Parts
Cause 3Ignition Coil

The ignition coil sends voltage to the spark plug while the engine is running. If the ignition coil is defective, the engine may not start. Before replacing the ignition coil, ensure that the spark plug is working properly. If you have confirmed that the spark plug is working properly, test the ignition coil with an ignition coil tester. If the ignition coil is defective, replace it.

Parts
Cause 4Recoil Starter

The recoil starter assembly engages the crankshaft to turn over the engine. If the recoil starter assembly is defective, it may not engage the crankshaft correctly. Remove the starter assembly and inspect it to determine if it is working properly. When you pull the starter rope, tabs extending from the pulley and cam should grab the hub on the engine, causing the engine to turn. When you release the rope, the tabs should retract and the rope should rewind back on the pulley.

Parts
Cause 5Start Switch

If the start switch is difficult to turn or works intermittently, replace it. To determine if the start switch is defective, use a multimeter to test it for continuity. The switch should have an open contact in the 'off' position and a closed contact in the 'on' position.

Parts
Cause 6Safety Switch

The safety switch can be tested with a multimeter to determine if it is defective.

Parts
Cause 7On - Off Switch

The on-off switch can be tested with a multimeter to determine if it is defective.

Parts
Cause 8Flywheel Key

The flywheel key might have sheared in half. The flywheel key is a small metal piece which fits into the crankshaft and engages with the flywheel. If the generator engine stops suddenly, the flywheel key may break in half. To determine if the flywheel key is broken, remove the flywheel from the engine and inspect the flywheel key. If the flywheel key is broken, replace it.