TradePro Furnace Not Blowing Enough

The part(s) or condition(s) listed below for the symptom Furnace not blowing enough are ordered from most likely to least likely to occur. Check or test each item, starting with the items at the top of the page.

Most Frequent Causes for Furnace not blowing enough

For the most accurate results, enter your model number.


Cause 1Blower Motor

Since the furnace's blower motor is the component that circulates the heated air through the home's venting, a defective blower motor will result in the furnace not blowing enough. You can use a multimeter to test the blower motor for electrical continuity, a continuous electrical path present in the motor, as well as determine if power is reaching the motor. You can also try turning the blower wheel by hand. If the wheel does not turn freely, it's likely the motor bearings have seized and the blower motor will need to be replaced.

Parts
Cause 2Register is Closed or Only Partially Opened

Some heat registers have adjustable louvers that allow the air flow to be restricted or shut off entirely. This would be used to cut off the air flow to a room that isn't being used or to restrict air flow to one room so more

Cause 3Blower Wheel and Housing

Over time the blower wheel and housing can become clogged with dust and debris. This will restrict the air flow, preventing the furnace from blowing enough. You can try cleaning the blower wheel with compressed air or with a soft bristle brush. Use caution when trying to clean the blower wheel as the fins are sharp and can be easily damaged. If the blower is damaged it will need to be replaced.

Parts
Cause 4Blower Housing

Over time the blower wheel and housing can become clogged with dust and debris. This will restrict the air flow, preventing the furnace from blowing enough. You can try cleaning the blower wheel with compressed air or with a soft bristle brush. Use caution when trying to clean the blower wheel as the fins are sharp and can be easily damaged. If the blower is damaged it will need to be replaced.

Parts
Cause 5Clogged Blower Wheel

Over time the blower wheel can become clogged with dust and debris. This will greatly affect the air flow circulating throughout the home. You can try cleaning the blower wheel with compressed air or with a soft bristle brush. Use caution when trying to clean the blower wheel as the fins are sharp and can be easily damaged. If the blower is damaged it will need to be replaced.

Cause 6Run Capacitor

The run capacitor provides voltage to the blower motor. If the capacitor is defective, the blower motor may not run resulting in the furnace not blowing enough. To determine if the capacitor has failed, test the capacitor with a multimeter. If the run capacitor is unable to hold and release a charge or is bulging or leaking, replace it.

Parts
Cause 7Capacitor

The capacitor provides voltage to the blower motor. If the capacitor is defective, the blower motor may not run resulting in the furnace not blowing enough. To determine if the capacitor has failed, test the capacitor with a multimeter. If the capacitor is unable to hold and release a charge or is bulging or leaking, replace it.

Parts
Cause 8Motor Control Board

The motor control board helps to maintain the desired motor speed of the blower. When the motor control board fails, the blower motor may not run at the correct speed or it may not run at all.

Parts
Cause 9Air Filter

Air Filter

Parts